3750 Prospect Ave, Riviera Beach, Florida 33404 USA

Get in touch with us 1-800-741-4376

Perry Gas System Options

Perry is pleased to provide high-pressure gas solutions in scenarios where bulk oxygen is either impractical or unavailable. We offer both high-pressure microbulk oxygen and air compressor solutions, tailored to deliver suitable oxygen or air configurations for small indoor storage options, compliant with relevant codes, as well as external outbuilding storage where applicable.

Perry is committed to delivering customized solutions, and the list below serves as a preliminary guide. We encourage you to schedule a consultation with Perry Engineering Services to explore the options that best suit your facility’s needs.

For inquiries, please contact us at 800-741-4376.

It is crucial to connect your chambers with approved gas systems to ensure safety and optimal functionality of your oxygen or air-pressurized system. Our technicians are equipped to perform hyperbaric chamber installations for your existing systems.

Please refer to the standard connections illustrated in the accompanying diagram.

Gas System Options

Name: Liquid Oxygen Mini-Bulk

Description: TECH-OS-904704 – Oxygen Services for Two Chambers Liquid oxygen dewar and vaporizer primary and secondary banks, bottled gas reserve, and automatic changeover manifold. Remote alarm panel in hyperbaric suite. Located in utility room or outbuilding.

Gas: O2

Number Chambers Supported: 1-2 

SCFM (LPM): 58.3 (1650)

Storage / Buffer: 19,400 ft3 

Name: Oxygen Generator – PSA

Description: ECH-O2-904973 – Oxygen 93 – Generate oxygen on-site up to 95% Purity (Oxygen 93). Air compressor, filter, dryer, pressure-swing-absorption tower, and buffer storage tanks located in utility room or outbuilding. Remote CO and O2 monitor/alarm panel in hyperbaric suite.

Gas: O2

Number Chambers Supported: 1-2 or 3-4 (duplex)

SCFM (LPM): 17.7 (500)

Storage / Buffer: 11060 gal

Name: Oxygen Generator – VPSA

Description: Generate oxygen on-site up to 95% Purity (Oxygen 93) – Premium system uses vacuum-pressure-swing-absorption, eliminating need for dryer and reducing maintenance requirements. Air compressor, filters, VPSA-tower, and buffer storage tanks located in utility room or outbuilding.

Remote CO and O2 monitor/alarm panel in hyperbaric suite.

Gas: O2

Number Chambers Supported: 2-3 or 4-6 (duplex)

SCFM (LPM): 21.18 (600) 

Storage / Buffer: 11060 gal

Name:15 Hp Screw Air – Compressor

Description: Pressurize chambers with air, save on oxygen consumption. Portable
installation through 36″ doorway in 12′ x4′ utility room. Premium Kaeser
compressor with worldwide service team. CO monitor/alarm panel in
hyperbaric suite.

Gas: Air

Number Chambers Supported: 1-2 (with BIBS)

SCFM (LPM): 71 (2010)

Storage / Buffer: 120 gal

Name: 210 HP Screw – Air Compressor

Description: Pressurize chambers with air, save on oxygen consumption. Twin
compressors enable continued partial operation if one is down. Portable
installation through 36″ doorwav in 15 5’x4′ utility room. Premium Kaeser
compressor with worldwide service team. CO monitor/alarm panel in
hvperbaric suite.

Gas: Air

Number Chambers Supported: 2-4 (with BIBS)

SCFM (LPM): 92 (2600)

Storage / Buffer: 120 gal

Name: + Kaeser KBS

Description: Optional add-on scrubs CO, water vapor, and odors. Necessary when air
compressor intake is near pollution sources.

Name: 15 HP Oil- Less Scroll
Air Compressor

Description: TECH-A-902856 – LP-SCR Compressor Package Pressurize chambers with air, save on oxygen consumption. Integral triplex design enables redundancy for continued operation. Portable installation through 36″ doorway in 12’x4′ utility room. Low-maintenance Powerex compressor.
CO monitor/alarm panel in hyperbaric suite.

Gas: Air

Number Chambers Supported: 1-2 (with BIBS)

SCFM (LPM): 45.6 (1290)

Storage / Buffer: 240 gal

Name: 20 HP Oil- Less Scroll
Air Compressor

Description: TECH-AP-905023 – 20HP Quadplex Medical Air Delivery System Pressurize chambers with air, save on oxygen consumption. Integral quadplex design enables redundancy for continued operation. Portable installation through 36″ doorway in 12 x4′ utility room. Low-maintenance Powerex compressor. CO monitor/alarm panel in hyperbaric suite.

Gas: Air

Number Chambers Supported: 2-4 (with BIBS)

SCFM (LPM): 60.8 (1720)

Storage / Buffer: 740 gal

Name: BIBS Oxygen – Bottled Supply

Description: Supplies oxygen for the patient mask to air-pressed chambers. High-
pressure H-cylinder manifold located in hyperbaric suite.

Gas: O2

Number Chambers Supported: 1-2 or 3-4 (duplex)

SCFM (LPM): 3.5 (100)

Storage / Buffer: 1,500 ft3

Name: BIBS Oxygen Concentrator

Description: Generate oxygen on-site up to 95% Purity (Oxygen 93) Compact integral
8x gas-membrane modules, no air compressor needed. Portable
installation in 2’x3′ space of hyperbaric suite, with small buffer tank and
bottled gas cylinder reserve in adjacent <100ft? utility room.

Gas: O2

Number Chambers Supported: 1-2 or 3-4 (duplex)

SCFM (LPM):2.8 (80)

Storage / Buffer: 120 gal

* All specifications are subject to change without notice.
* All installations must be in accordance with local codes
permitting, and AHJ requirements.